TEL: +86 010 63326036
ENAIL:sales@jwgb.net
TEL: +86 010 63326024
EMAIL:sales@jwgb.net

Micro 100

Outline

The JWGB 100 Series can accurately produce surface area and pore size results of powder materials. According to the different test functions, this series of instruments are divided into three types, there are A, B, and C, the C type is configured with 1 torr or 0.1 torr high-sensitive pressure sensors and turbo molecular pump with ultimate pressure of 10-8 Pa, it can effectively take microporous analysis of microporous materials such as molecular sieve, catalyst, activated carbon, and other microporous materials.

Features

  • Test Module
  • Internal temperature of test module can be controlled through Real-time monitoring, ensuring accuracy of adsorption detection.
  • Saturated Vapor Pressure P0
  • Using independent P0 pressure sensor for P0 value by inching test, guarantees the reliability of experimental data. Atmospheric pressure input method to determine P0 also be selected.
  • Datasheet
  • Vacuum System
  • It’s a multi-channel, adjustable, and parallel vacuum system. Vacuum degree of this system can be controlled in segments. This design prevents the sample from being pumped into analyzer. Meanwhile, a delicate part was designed for ensuring cleanliness of vacuum system, minimizing dust pollution.
  • Sample Preparation System
  • In addition to two pretreatment stations, the other two analysis stations can be used in preparing samples. There is no interference between pretreatment stations and analysis stations. Degas temperature can be set individually and controlled from ambient to 400 ℃.
  • Micropore Distribution
  • Accurately apply the HK method, SF method and other micropore analysis model, the aperture deviation of micropore is less than 0.02 nm.
  • Pressure Sensor
  • Micro 100C with 1torr (selectable 0.1torr) makes the partial pressure of P/P0 up to 10-7 - 10-8 (N2/77K) in the physical adsorption analysis.
  • Datasheet
  • Cold Free Space
  • Cold free space can be corrected by Helium automatically, ensuring accuracy of test results.
    This calibration method is suitable for testing of any powder or particle material.
  • Control of Liquid Nitrogen level
  • Using High volume (3L) Dewar flasks and working with the seal cover assure a constant thermal profile along the length of sample tubes and P0 tubes throughout testing process.
  • Turbo Molecular Pump
  • Molecular pump is a standard configuration part on the Micro 100C. The ultimate pressure is up to 10-8 Pa, providing a strong support for micropore analysis in the ultra-low pressure. The smallest micro-pore diameter can be tested is 0.35 nm.

Software

  • JWGB-BK Software is intelligent software in operation control, data acquisition, calculation and analysis and report generation on the Windows platform. This software can communicate with the host through the LAN port and remotely control many instruments at the same time.
  • Clear tabular reports include:
      Adsorption and desorption isotherms
      Single-/Multipoint BET surface area
      Langmuir surface area
      STSA-surface area
      pore size distribution according to BJH
      t-plot
      Dubinin-Radushkevich
      Horvath-Kawazoe
      Saito-Foley
  • Datasheet
  • Datasheet
  • JWGB-BK Software adopts a unique intake control method, the pressure in adsorption and desorption process is optimally set in six- stage; this flexible design is helpful for improving test efficiency.
  • Datasheet
  • Changes of the pressure and temperature inside the manifold can be observed directly in the test interface which is convenient for sample test and instrument maintenance.
    Current state of analyzer can be intuitively understood with the indicator light and event bar.
    Each adsorption equilibrium process is dynamically displayed on the test interface. Adsorption characteristics of the sample can be easily understood.
  • Datasheet

Case

  • BET repeatability is only 0.0015 m2 / g in the test of very low surface area powder
  • Datasheet Datasheet
  • Analysis value of pore size distribution in activated carbon materials as follows:
  • Datasheet Datasheet
  • Microporous analysis Report of carbon materials as below:
  • Datasheet Datasheet

Specification

FeatureMeso 100A Micro 100BMicro 100C
Adsorbed GasNon corrosive gases, such as N2, Ar, Kr, H2, O2, CO2, CO, NH3, CH4, etc.
Pressure Sensor at
Analysis Station
1000 torr1000 torr,10 torr 1000 torr,
10 torr, 1 torr (optional 0.1 torr)
Accuracy: ±0.15% (F.S.)
Pressure Sensor at P0 Station1000 torr
(Accuracy: ±0.15% (F.S.)
Degas System 2 ectopic vacuum heating degas station;
Samples on analysis bits can be degassed simutaneously.
Degas TemperatureAmbient to 400 ℃. Free to set up target temperature.
Cold Trap 1
Vacuum Pump Two-stage rotary vane mechanical vacuum pump,
the trtimate vacuum is 6.7*10-2 Pa
Turbo molecular pump (trtimate vacuum 10-8 Pa) and front mechanical vacuum pump
Analysis Port Samples on the 2 analysis bits can be tested alternately (including P0 test).
Test Principle Gas adsorption by static-volumetric analysis
Measurement Range of
Specific Surface Area
0.0005 m2/g to the infinity;
Standard sample repetition is less than ± 1.0%
Test Range of Pore 0.35 nm-500 nm; 0.35 nm-500 nm; 0.35 nm-500 nm;
Diameter repeatability of pore size is less
than 0.2 nm in the accurate
analysis of porous materials
which size is more than 2 nm
repeatability of pore size is less
than 0.2 nm in the accurate
analysis 0.7 nm-2 nm micropore.
repeatability of pore size is less
than 0.2 nm in the accurate
analysis 0.35 nm-2 nm micropore.
Range of Relative Pressure P/P0 10-5-0.99810-6-0.998 10-8-0.998
Minimum Pore Volume 0.0001 cm3/g
Overall Dimension Depth: 870 mm; width: 570 mm; height: 890 mm; weight: 80 Kg -90 Kg
Ambient Temperature15-40 oC
Related Humidity30%-60%
Electrical SupplyAC220 V ± 20 V, 50/60 HZ, maximum power 300W;

Specification

Applied FieldTypical Materials Details
Material Researchceramic powder, metal powder, nanotubeAccording to surface area value of nanotube, hydrogen storage capacity can be predicted.
Chemical Engineeringcarbon black, amorphous silica, zinc oxide, titanium dioxideIntroduction of carbon black in rubber matrix can improve mechanical properties of rubber products. Surface area of carbon black is one of the important factors affecting the reinforcement performance of rubber products.
New Energylithium cobalt, lithium manganateIncreasing surface area of electrode can improve Electrochemical reaction rate and promote iron exchange in negative electrode.
Catalytic Technologiesactive alumina oxide, molecular sieve, zeoliteActive surface area and pore structure influence reaction rate.